V Reduce carriage speed (n) for yarn
carrier (n = 0..3). The speed is reduced to
75% from carriage reversal point until
achievement of the operating range of
the yarn carrier. Finally it can be chosen
between the following possibilities:
1 = Acceleration up to 100%
2 = Braking down to 50%, maintain
speed over a fabric width of 2 inches,
acceleration up to 100%
3 = Braking down to 50%, maintain
speed over a fabric width of 5 inches,
acceleration up to 100%
0 = Cancelling out of carriage speed
specific to yarn carrier