12 Appendix
12.3.2 List of Parameters
12-36
* When Pn50A.0 is set to 0 for the input signal standard allocation mode, the following modes are compatible:
Pn50A.1 = 7, Pn50A.3 = 8, and Pn50B.0 = 8.
Parameter
No.
Name Setting Range Unit
Factory
Setting
Setting
Validation
Reference
Section
Pn50A Input Signal Selections 1
−−2100
After
restart
0
1
2
3
4
5
6
7
8
9
A
B
0
1
ON when CN1-40 input signal is ON (L-level).
ON when CN1-41 input signal is ON (L-level).
ON when CN1-42 input signal is ON (L-level).
ON when CN1-43 input signal is ON (L-level).
ON when CN1-44 input signal is ON (L-level).
ON when CN1-45 input signal is ON (L-level).
ON when CN1-46 input signal is ON (L-level).
Sets signal ON.
Sets signal OFF.
OFF when CN1-40 input signal is OFF (H-level).
OFF when CN1-41 input signal is OFF (H-level).
OFF when CN1-42 input signal is OFF (H-level).
OFF when CN1-43 input signal is OFF (H-level).
OFF when CN1-44 input signal is OFF (H-level).
OFF when CN1-45 input signal is OFF (H-level).
OFF when CN1-46 input signal is OFF (H-level).
/S-ON Signal Mapping
Signal Polarity: Normal; Servo ON when ON (L-level)
Signal Polarity: Reverse; Servo ON when OFF (H-level)
(Refer to "8.3.1 Setting the Servo ON Signal.")
0 to F
Same as /S-ON
/P-CON Signal Mapping (P control when ON (L-level))
(Refer to "9.4.4 Proportional Control Operation (Proportional Operation Reference).")
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
C
D
E
F
Uses the sequence input signal terminals with standard allocation.
Changes the sequence input signal allocation for each signal.
Input Signal Allocation Mode
(Refer to "7.3.2 Input Circuit Signal Allocation.")
P-OT Signal Mapping (Overtravel when OFF (H-level))
(Refer to "8.3.3 Setting the Overtravel Limit Function.")
0
1
2
3
4
5
6
7
8
9
A
B
Forward run allowed when CN1-40 input signal is ON (L-level).
Forward run allowed when CN1-41 input signal is ON (L-level).
Forward run allowed when CN1-42 input signal is ON (L-level).
Forward run allowed when CN1-43 input signal is ON (L-level).
Forward run allowed when CN1-44 input signal is ON (L-level).
Forward run allowed when CN1-45 input signal is ON (L-level).
Forward run allowed when CN1-46 input signal is ON (L-level).
Forward run prohibited.
Forward run allowed.
Forward run allowed when CN1-40 input signal is OFF (H-level).
Forward run allowed when CN1-41 input signal is OFF (H-level).
Forward run allowed when CN1-42 input signal is OFF (H-level).
Forward run allowed when CN1-43 input signal is OFF (H-level).
Forward run allowed when CN1-44 input signal is OFF (H-level).
Forward run allowed when CN1-45 input signal is OFF (H-level).
Forward run allowed when CN1-46 input signal is OFF (H-level).
C
D
E
F

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Sigma II Series and is the answer not in the manual?

YASKAWA Sigma II Series Specifications

General IconGeneral
BrandYASKAWA
ModelSigma II Series
CategoryController
LanguageEnglish

Related product manuals