EasyManuals Logo

YASKAWA V1000 Series Technical Manual

YASKAWA V1000 Series
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
3.8 I/O Connections ...................................................................................................................................... 48
Sinking/Sourcing Mode Switch ..................................................................................................................... 48
3.9 Main Frequency Reference ..................................................................................................................... 50
Terminal A2 Switch ................................................................................................................................... 50
3.10 MEMOBUS/Modbus Termination ............................................................................................................ 51
3.11 Braking Resistor..................................................................................................................................... 52
Installation ............................................................................................................................................... 52
3.12 Wiring Checklist ..................................................................................................................................... 53
4. START-UP PROGRAMMING & OPERATION ............................................................................ 55
4.1 Section Safety......................................................................................................................................... 56
4.2 Using the Digital LED Operator............................................................................................................... 58
Keys, Displays, and LEDs............................................................................................................................ 58
Digital Text Display .................................................................................................................................... 59
LED Screen Displays.................................................................................................................................. 59
LO/RE LED and RUN LED Indications ........................................................................................................... 59
Menu Structure for Digital LED Operator......................................................................................................... 60
4.3 The Drive and Programming Modes ....................................................................................................... 61
Navigating the Drive and Programming Modes................................................................................................. 61
Changing Parameter Settings or Values ......................................................................................................... 63
Verifying Parameter Changes: Verify Menu ..................................................................................................... 64
Switching Between LOCAL and REMOTE....................................................................................................... 64
Parameters Available in the Setup Group........................................................................................................ 64
4.4 Start-up Flowcharts ................................................................................................................................ 66
Flowchart A: Basic Start-Up and Motor Tuning ................................................................................................. 67
Subchart A1: Simple Motor Set-Up with Energy Savings or Speed Search using V/f Mode........................................ 67
Subchart A2: High Performance Operation Using Open Loop Vector Motor Control ................................................. 68
Subchart A3: Operation with Permanent Magnet Motors ................................................................................... 68
4.5 Application Presets ................................................................................................................................ 70
Application Preset Function (APPL) ............................................................................................................... 70
Application Presets: A1-06........................................................................................................................... 70
User Parameters: A2-01 to A2-32.................................................................................................................. 74
User Parameter Automatic Selection: A2-33 .................................................................................................... 74
4.6 Basic Drive Setup Adjustments .............................................................................................................. 75
Control Mode Selection: A1-02 ..................................................................................................................... 75
Initialize Parameter Values: A1-03................................................................................................................. 75
Application Presets: A1-06........................................................................................................................... 75
DWEZ Function Selection: A1-07 .................................................................................................................. 75
Frequency Reference Source: b1-01.............................................................................................................. 76
Run Command Input Selection: b1-02 ............................................................................................................ 77
Stopping Method Selection: b1-03................................................................................................................. 78
Acceleration/Deceleration: C1-01 to C1-11...................................................................................................... 80
Drive Duty Mode and Carrier Frequency Selection: C6-01 and C6-02 ................................................................... 82
Drive Input Voltage Setting: E1-01................................................................................................................. 83
V/f Pattern Selection: E1-03 ......................................................................................................................... 84
Motor Parameters: E2-01 through E2-12 (Manually Entering Parameter Settings) ................................................... 85
Digital Outputs H2-01 to H2-03 ..................................................................................................................... 86
Analog Outputs: H4-01 to H4-03 ................................................................................................................... 86
Motor Protection: L1-01 and L1-02 ................................................................................................................ 87
Drive Status Monitors: U1-01 to U6-19 ........................................................................................................... 89
4.7 Test Run ................................................................................................................................................. 91
Powering Up the Drive and Operation Status Display ........................................................................................ 91
Auto-Tuning.............................................................................................................................................. 91
No-Load Operation..................................................................................................................................... 95
Operating with the Load Connected............................................................................................................... 96
Verifying Parameter Settings and Backing Up Changes ..................................................................................... 96
Jog Operation: FJOG/RJOG ........................................................................................................................ 97
Multi-Step Speed Operation (4-Step Speed).................................................................................................... 98
4.8 Test Run Checklist ............................................................................................................................... 100
5. PARAMETER DETAILS............................................................................................................. 101
5.1 A: Initialization...................................................................................................................................... 102
A1: Initialization ....................................................................................................................................... 102
A2: Preferred Parameters .......................................................................................................................... 108
Table of Contents
4
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)

Table of Contents

Other manuals for YASKAWA V1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 Series and is the answer not in the manual?

YASKAWA V1000 Series Specifications

General IconGeneral
ModelV1000 Series
SeriesV1000
Output Frequency0.1 to 400 Hz
Overload Capacity150% for 60 seconds
TypeAC Drive
Control MethodV/f Control
Input Voltage200-240V, 380-480V
Output Voltage0 to Input Voltage
Power Range0.1 to 18.5 kW
Horsepower0.2 to 25 HP
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication InterfacesModbus RTU
EnclosureIP20
Ambient Temperature-10 to +50°C
Storage Temperature-20 to +60°C
Humidity5 to 95% RH (non-condensing)
Cooling MethodFan Cooled