Fan Module Alarms Introduction
1-203
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
SHOW ALARMS PORT
Syntax
SHOW ALARMS [ PORT [ ={ port-list | ALL } ] ] [ FULL ]
Description Shows alarms for a specified set of ports or all ports
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Example
SHOW ALARMS PORT=3.0,3.1
--- Interface(Port) Alarms ---
Interface Fault Severity Time Stamp
------------ -------------------------------- -------- --------------
3.0 Loss of Link Major 03:07:26 07/30
3.1 Loss of Link Major 03:07:26 07/30
Option Description Default Value
PORT The comma-separated list of port(s) that will have its
alarms displayed.
ALL
FULL Includes more descriptive information.