Configuring BPDU Cop Introduction
4-113
Software Reference for SwitchBlade x3100 Series Switches (Layer Two Switching)
SHOW TRACE STP
Syntax
SHOW TRACE STP [ INSTANCE={ stpname | mstid | MAIN | ALL } ] [
EVENT={ BPDU | ALL } ] [ INTERFACE={ type:id-range | id-range |
ifname-list | ALL } ]
Description Displays the current set of trace criteria for STP.
Options The following table gives the range of values for each option that can be specified with
this command and a Default Value (if applicable).
Example SHOW TRACE STP
--- STP Traces ----------------------------------------------------------------
Trace Event MSTID Interfaces
------------ ----------------- --------------- ---------------
1 BPDU 0 0.22
------------------------------------------------------------------------------
Option Description Default Value
INSTANCE The instance where the trace will be displayed.
EVENT Specify whether BPDU or ALL will be shown ALL
INTERFACE The interface(s) where the trace will be displayed.