EasyManuals Logo

Allied Telesis SwitchBlade x3100 Series User Manual

Allied Telesis SwitchBlade x3100 Series
940 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #433 background imageLoading...
Page #433 background image
Configuring BPDU Cop Introduction
4-113
Software Reference for SwitchBlade x3100 Series Switches (Layer Two Switching)
SHOW TRACE STP
Syntax
SHOW TRACE STP [ INSTANCE={ stpname | mstid | MAIN | ALL } ] [
EVENT={ BPDU | ALL } ] [ INTERFACE={ type:id-range | id-range |
ifname-list | ALL } ]
Description Displays the current set of trace criteria for STP.
Options The following table gives the range of values for each option that can be specified with
this command and a Default Value (if applicable).
Example SHOW TRACE STP
--- STP Traces ----------------------------------------------------------------
Trace Event MSTID Interfaces
------------ ----------------- --------------- ---------------
1 BPDU 0 0.22
------------------------------------------------------------------------------
Option Description Default Value
INSTANCE The instance where the trace will be displayed.
EVENT Specify whether BPDU or ALL will be shown ALL
INTERFACE The interface(s) where the trace will be displayed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis SwitchBlade x3100 Series and is the answer not in the manual?

Allied Telesis SwitchBlade x3100 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelSwitchBlade x3100 Series
CategorySwitch
LanguageEnglish

Related product manuals