Introduction SuperLoop Prevention
Software Reference for SwitchBlade x3100 Series Switches (Layer Two Switching)
4-130
4.6.10 SuperLoop Prevention
With interconnected topologies, it is possible to have a condition called a SuperLoop, if all of the following
conditions exist.
The network has two or more EPSR domains.
The protected (data) VLAN overlaps two or more EPSR domains.
The EPSR domains and the overlapping protected VLANs share a common link.
SHOW the status of the EPSR domain.
8
show epsr a0
--- EPSR Domain Information ---
EPSR Domain Name...................... allied
EPSR Domain Node Type................. Transit
EPSR Domain State..................... LINKS-UP
MAC Address of Master Node............ 00:0C:25:1F:80:09
EPSR Domain Status.................... Enabled
Control Vlan.......................... 3501
Enhanced Recovery..................... ON
Ring Interface # 1.................... ETH:[8.0]
Physical State of Ring Interface # 1.. UP
Ring Interface # 1 Type............... UPSTREAM
Ring Interface # 1 State.............. PHYSICALLY FORWARDING
Ring Interface # 1 Priority........... 0
Ring Interface # 1 Priority Rank...... 0
Ring Interface # 2.................... ETH:[8.2]
Physical State of Ring Interface # 2.. UP
Ring Interface # 2 Type............... DOWNSTREAM
Ring Interface # 2 State.............. PHYSICALLY FORWARDING
Ring Interface # 2 Priority........... 0
Ring Interface # 2 Priority Rank...... 0
Data Vlans............................ 3502
TABLE 4-18 Configuration Procedure for EPSR - Configure a Transit Node
Step Command Description/Notes