In this example, the SNMP community is configured as READ only.
TABLE 7-6 Configuration Procedure for SNMP
Step Command Description
Show the initial SNMP configuration. The initial status of SNMP is disabled.
1
SHOW SNMP Shows that SNMP is disabled.
Use the ENABLE SNMP command so you can create an SNMP community
2
ENABLE SNMP Enables SNMP for the device.
3
SHOW SNMP Shows that SNMP is now enabled.
Enable SNMP authentication traps.
4
ENABLE SNMP AUTHENTICATE_TRAP Captures authentication failure traps.
Create the community, with the community name and the list of trusted trap hosts and management stations.
5
CREATE SNMP COMMUNITY=public
V2CTRAPHOST=172.16.34.2
MANAGER=172.16.32.3 TRAPHOST=
172.16.22.8
The SNMP community with the name “public” is
created and the trap hosts are defined.
Enable the SNMP community, and then enable traps for that community
6
ENABLE SNMP COMMUNITY=public Enables the SNMP community
7
ENABLE SNMP COMMUNITY=public TRAP Enables traps for the SNMP community.
Show the SNMP community information.
8
SHOW SNMP COMMUNITY=public
--- SNMP Community Information -----------------
Name.................................. public
-------------------------------------- ---------
Access................................ READ-ONLY
Status................................ ENABLED
Traps................................. ENABLED
Open Access........................... NO
Manager...............................172.16.32.3
TrapHost..............................172.16.22.8
v2cTrapHost...........................172.16.34.2
Displays the SNMP community settings.