CDM-570/570L Satellite Modem with Optional IP Module Revision 12
Appendix D MN/CDM570L.IOM
D–33
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
BUC PLL Alarm N/
1 byte,
value of 0 or 1
Query only.
BUC PLL lock state, where:
1=Unlocked
0=Locked
If not available, response is 9.
Note: This command is only valid when the FSK and BUC power are turned On.
Example: BPA=0 (BUC PLL is locked)
N/
(see Description of
Arguments)
BUC Power Control
BPC= 1 byte,
value of 0 or 1
Command or Query
0=Disable BUC DC Power
1=Enable BUC DC Power
Example: BPC=0 (BUC DC power disabled)
BPC=
(see Description of
Arguments)
BUC Software
Version
N/
Indicates the BUC software version, in the form xx.
If not available, response is 00
Note: This command is only valid when the FSK and BUC power are turned On.
Example: BSV=05 (Software version 05)
N/
(see Description of
Arguments)
BUC Temperature N/
BUC temperature is returned, in the form sxx, where:
s = sign (+ or - character)
xx = value
If not available, response is –99
Note: This query is only valid when the FSK and BUC power are turned On.
Example: BUT=-13 (BUC temperature is -13 degrees C)
N/
(see Description of
Arguments)