Comtech EF Data CDM-570 - Maint | Operations....................................................................................................... 13-62; Maint | Reboot............................................................................................................. 13-64; Maint | Save................................................................................................................ 13-63; Maint | Unit Info......................................................................................................... 13-61

Comtech EF Data CDM-570
512 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDM-570 Satellite Modem with Optional IP Module Revision 12
Base Modem Web Server Interface MN/CDM570L.IOM
7–14
7.3.3.3 Config Mdm | AUPC
For details pertaining to AUPC configuration and operation, see Chapter 9.
AUTOMATIC UPLINK POWER CONTROL (AUPC).
Use this page to configure Automatic Uplink Power Control (AUPC).
Figure 7-10. Config Mdm | AUPC page
With AUPC, a local modem is permitted to adjust its own output power level in order to attempt
to maintain the E
b
/N
0
at the remote modem.
AUPC
AUPC Enable: Use the drop-down menu to select AUPC operation as either Enabled or
Disabled.
Rem Demod Target E
b
/N
0
: Type in a value, in dB, from 0.0 to 14.9.
Tx Power Max Increase: Use the drop-down menu to select a value, in dB, from 0 to 9.
Max Pwr Reached Action: Use the drop-down menu to set the action as No Action or
Generate Tx Alarm.
Rem Demod Unlock Action: Use the drop-down menu to set the action as Go to Nominal
Power or Go to Maximum Power.
Click [Submit] to save changes made to this page.