DEQX User Manual
10.5 RUN THE MEASUREMENT
Screen 6. DEQX-Cal will upload the test signal to the DEQX, as shown by the
“Initializing DEQX” indicator.
When the indicator changes to “Playing test signal,” adjust the measurement signal
level as described on page 50. For a room measurement, however, the input level
should typically be peaking in the range of 75–85 dB.
Click Run to proceed.
Screen 7. DEQX-Cal runs through a series of steps to measure the selected speakers
and subwoofers:
The measurement proceeds in a similar manner as for a speaker measurement, but for
each selected speaker and subwoofer in turn.
As the measurement of each speaker or subwoofer completes, the wizard displays its
confidence level. With room measurements, the confidence level is much less critical
than it is for speaker measurements, as room measurements are not used to directly
generate correction filters. As long as DEQX-Cal completes each measurement item
with a green tick, you can consider the measurement to be acceptable.