EasyManua.ls Logo

Fujitsu PRIMERGY TX1320 M4 - Removing the M.2 SSD; Preliminary Steps

Fujitsu PRIMERGY TX1320 M4
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
292 Upgrade and Maintenance Manual TX1320 M4
System board and components
I The M.2 SSD can be used only for boot device. Do not use VMFS on the
M.2 SSD because of not meeting required endurance. For more
information, see the VMware Knowledge Base 2145210.
http://kb.vmware.com/s/article/2145210
I For Japan
In order to setup the ESXi, see the corresponding version of the "VMware
vSphere Software Description" from the following URL and reinstall ESXi
to the M.2 SSD.
http://jp.fujitsu.com/platform/server/primergy/software/vmware/manual/
14.5.2 Removing the M.2 SSD
14.5.2.1 Preliminary steps
Ê "Shutting down the server" on page 49
Ê "Disconnecting the power cord" on page 50
Ê "Getting access to the component" on page 51
Ê If applicable, "Removing expansion cards" on page 187.
Ê If applicable, remove the HDD fan module 2.5-inch HDD variant, see section
"Replacing the HDD fan module" on page 164.
Ê If applicable, disconnect the Oculink cables from the PCIe backplane.
Ê If applicable, disconnect the SATA cable of the ODD from the system board.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: Phillips PH1 / (+) No. 1 screw driver
Hexagon screw driver (for moving the screw to another hexagon
stand-off)