294 Upgrade and Maintenance Manual TX1320 M4
System board and components
14.5.2.3 Concluding steps
Ê If applicable, connect the SATA cable of the ODD from the system board.
Ê If applicable, connect the Oculink cables to the PCIe backplane.
Ê If applicable, "Installing expansion cards" on page 180.
Ê If applicable, install the HDD fan module 2.5-inch HDD variant, see section
"Replacing the HDD fan module" on page 164.
Ê "Reassembling" on page 57
Ê "Connecting the power cord" on page 60
Ê "Switching on the server" on page 63
14.5.3 Replacing the M.2 SSD
14.5.3.1 Preliminary steps
Ê "Locating the defective server" on page 47
Ê "Shutting down the server" on page 49
Ê "Disconnecting the power cord" on page 50
Ê "Getting access to the component" on page 51
Ê If applicable, "Removing expansion cards" on page 187.
Ê If applicable, remove the HDD fan module 2.5-inch HDD variant, see section
"Replacing the HDD fan module" on page 164.
Ê If applicable, disconnect the Oculink cables from the PCIe backplane.
Ê If applicable, disconnect the SATA cable of the ODD from the system board.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Software: 15 minutes
Tools: Phillips PH1 / (+) No. 1 screw driver