Basic software procedures
Ê Select the number of a memory module with a status other than "OK" or
"Not available".
Ê Repeat the step above until all memory modules show the "OK" status.
Ê Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
5.2.7.2 CPUs
ServerView Operations Manager may report a defective CPU in case of a
critical error.
I Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.
Using ServerView Maintenance Tools (Windows only)
Ê Launch the ServerView Maintenance Tools:
Start > Apps > Fujitsu > Maintenance Tools
Ê Choose the CPU status tab.
Ê Select the CPU which shows the pre-failure status.
Ê Click on Reset Status.
Ê Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.