Environmental specications
Table 14-9 Printer environmental specications
Temperature range Humidity range Temperature gradient
Operating for optimal print
quality
20 to 25°C (68 to 77°F) 30 to 60% relative humidity 10°C/h (18°F/h) or less
Operating for standard printing 15 to 30°C (59 to 86°F) 20 to 70% relative humidity 10°C/h (18°F/h) or less
Not operating, in transport or
storage, ink in tubes
5 to 55°C (41 to 131°F) 90% relative humidity at 55°C
(131°F)
10°C/h (18°F/h) or less
Not operating, in transport or
storage, no ink in tubes *
–25 to 55°C (–13 to 131°F) 90% relative humidity at 55°C
(131°F)
10°C/h (18°F/h) or less
* If the printer is going to be kept at a temperature of less than 5°C, call your service representative to empty
the ink from the tubes.
Maximum operating altitude: 3000 m (10000 ft)
The printer should not be exposed to direct sunlight or any other strong light source, and it should not be
used in a dusty environment.
Acoustic specications
Printer acoustic specications (declared according to ISO 9296).
Table 14-10 Printer acoustic specications
Idle sound power level 8.8 B (A)
Operating sound power level 8.2 B (A)
Idle sound pressure at bystander position < 60 dB (A)
Operating sound pressure at bystander position < 67 dB (A)
< 75 db (A) during cool-down