Parameter
Address Name / seng range / [default seng] Info
0x2D4C:001 Thermisches Modell Motorauslastung (i²xt): Motor
ulisaon (i²xt)
1 ... [60] ... 36000 s
Seng of the me constant for the winding.
0x2D4C:002 Thermisches Modell Motorauslastung (i²xt): Thermal
me constant - laminaons
1 ... [852] ... 36000
s
Seng of the me constant for the laminated core.
0x2D4C:003 Thermisches Modell Motorauslastung (i²xt): Winding
inuence
0 ... [27] ... 100 %
Part of the thermal motor model:
distribuon factor of the copper wind-
ing inuence.
0x2D4C:004 Thermisches Modell Motorauslastung (i²xt): Starng
value
0 ... [0] ... 250 %
Value for inialising the
lters for the thermal motor overload monitor-
ing (seng in % of the permissible full load).
Conguring the motor control
Mot
or protecon
Motor overload monitoring (i²*t)
291