21 A/D CONVERSION INSTRUCTIONS
21.3 Restoring the User Range Setting Values
1749
21
For R60ADV8, R60ADI8, R60AD8-G
Operand: (s)
Device Item Description Setting range Set by
+0 System area 
+1 Completion status The instruction completion status is stored.
0: Completed successfully
Other than 0: Completed with an error (error code)
System
+2 Save data type setting
*1
Used to store the set value that was set for Save data type
setting (s)+2 in the G(P).OGLOAD instruction.
0: Voltage specification
1: Current specification
0000H to 00FFH System
+3 System area 
+4 CH1 Factory default setting offset value (L) System
+5 CH1 Factory default setting offset value (H) System
+6 CH1 Factory default setting gain value (L) System
+7 CH1 Factory default setting gain value (H) System
+8 CH2 Factory default setting offset value (L) System
+9 CH2 Factory default setting offset value (H) System
+10 CH2 Factory default setting gain value (L) System
+11 CH2 Factory default setting gain value (H) System
+12 CH3 Factory default setting offset value (L) System
+13 CH3 Factory default setting offset value (H) System
+14 CH3 Factory default setting gain value (L) System
+15 CH3 Factory default setting gain value (H) System
+16 CH4 Factory default setting offset value (L) System
+17 CH4 Factory default setting offset value (H) System
+18 CH4 Factory default setting gain value (L) System
+19 CH4 Factory default setting gain value (H) System
+20 CH5 Factory default setting offset value (L) System
+21 CH5 Factory default setting offset value (H) System
+22 CH5 Factory default setting gain value (L) System
+23 CH5 Factory default setting gain value (H) System
+24 CH6 Factory default setting offset value (L) System
+25 CH6 Factory default setting offset value (H) System
+26 CH6 Factory default setting gain value (L) System
+27 CH6 Factory default setting gain value (H) System
+28 CH7 Factory default setting offset value (L) System
+29 CH7 Factory default setting offset value (H) System
+30 CH7 Factory default setting gain value (L) System
+31 CH7 Factory default setting gain value (H) System
+32 CH8 Factory default setting offset value (L) System
+33 CH8 Factory default setting offset value (H) System
+34 CH8 Factory default setting gain value (L) System
+35 CH8 Factory default setting gain value (H) S
ystem
+36 CH1 User range setting offset value (L) System
+37 CH1 User range setting offset value (H) System
+38 CH1 User range setting gain value (L) System
+39 CH1 User range setting gain value (H) System
+40 CH2 User range setting offset value (L) System
+41 CH2 User range setting offset value (H) System
+42 CH2 User range setting gain value (L) System
+43 CH2 User range setting gain value (H) System
+44 CH3 User range setting offset value (L) System
b15 b3b4b5b6b7 b2 b1 b0
0
CH4CH5CH6CH7CH8 CH3 CH2 CH1