APPX
Appendix 1 Instruction Processing Time
2023
A
ORTM> When not executed 0.00588
When compared with the specified time: Continuity 2.700 9.300
When compared with the specified time: Non-continuity 2.800 9.300
When compared with the current time: Continuity 5.100 15.100
When compared with the current time: Non-continuity 5.100 15.100
ORTM<= When not executed 0.00588
When compared with the specified time: Continuity 2.700 9.200
When compared with the specified time: Non-continuity 2.600 9.300
When compared with the current time: Continuity 5.000 14.900
When compared with the current time: Non-continuity 4.900 15.000
ORTM< When not executed 0.00588
When compared with the specified time: Continuity 2.700 9.400
When compared with the specified time: Non-continuity 2.700 9.400
When compared with the current time: Continuity 5.000 14.800
When compared with the current time: Non-continuity 4.900 14.900
ORTM>= When not executed 0.00588
When compared with the specified time: Continuity 2.700 9.200
When compared with the specified time: Non-continuity 2.500 9.200
When compared with the current time: Continuity 4.900 14.900
When compared with the current time: Non-continuity 4.900 14.900
TCMP 4.200 7.800
TZCP 4.700 9.000
S.DATERD 3.500 11.600
S.DATE+ No carry 3.500 7.600
Carry 3.600 7.600
S.DATE- No borrow 3.600 8.000
Borrow 3.500 7.800
DUTY 2.400 6.600
TIMCHK 2.200 4.800
HOURM 2.900 6.200
DHOURM 2.900 6.200
RFS (X) (n)=1 5.500 15.500
(n)=64 13.000 33.800
RFS (Y) (n)=1 4.700 14.900
(n)=64 9.000 29.300
COM When only I/O refresh is selected 6.500 19.700
When only CC-Link IE Controller Network refresh is selected (control station side) 17.500 34.700
When only CC-Link IE Field Network refresh is selected (master station side) 17.700 37.400
When only CC-Link IE Controller Network refresh is selected (normal station side) 18.800 31.800
When only CC-Link IE Field Network refresh is selected (local station side) 18.100 36.000
When only CC-Link IE Field Network Basic refresh is selected 7.7 20.4
When only MELSECNET/H network refresh is selected (control station side) 19.000 40.000
When only MELSECNET/H network refresh is selected (normal station side) 19.400 38.600
When only an intelligent function module is selected 6.800 11.500
Refresh using CPU buffer memory in the multiple CPU system (during END
processing)
3.800 12.100
Import of input/output outside the group of multiple CPU system
Input: 64 points + output: 64 points
3.800 12.700
Device/label access service processing
(Communication with the engineering tool, GOT, or other external devices)
7.100 23.600
Instruction name Condition Processing time (s)
Minimum Maximum