Appendix 1 Instruction Processing Time
S.ZCOM When only CC-Link IE Controller Network refresh is selected (control station side) 18.700 51.600
When only CC-Link IE Field Network refresh is selected (master station side) 22.300 51.500
When only CC-Link IE Controller Network refresh is selected (normal station side) 17.000 38.000
When only CC-Link IE Field Network refresh is selected (local station side) 21.000 41.100
When only MELSECNET/H network refresh is selected (control station side) 20.200 56.900
When only MELSECNET/H network refresh is selected (normal station side) 20.600 55.500
FROM Reading buffer memory, (n)=1 3.700 4.300
Reading buffer memory, (n)=1000 38.000 55.600
Reading host CPU buffer memory, (n)=1 1.100 1.500
Reading host CPU buffer memory, (n)=320 14.100 27.000
Reading another CPU buffer memory, (n)=1 3.700 4.300
Reading another CPU buffer memory, (n)=320 21.900 39.500
DFROM Reading buffer memory, (n)=1 4.000 5.500
Reading buffer memory, (n)=500 39.400 69.400
Reading host CPU buffer memory, (n)=1 1.200 2.800
Reading host CPU buffer memory, (n)=320 21.900 42.900
Reading another CPU buffer memory, (n)=1 3.800 5.500
Reading another CPU buffer memory, (n)=320 32.300 66.300
TO Writing to buffer memory, (n)=1 2.100 2.700
Writing to buffer memory, (n)=1000 45.000 65.500
Writing to host CPU buffer memory, (n)=1 0.900 1.200
Writing to host CPU buffer memory, (n)=320 11.200 26.600
DTO Writing to buffer memory, (n)=1 2.400 4.000
Writing to buffer memory, (n)=500 44.400 71.000
Writing to host CPU buffer memory, (n)=1 1.000 2.600
Writing to host CPU buffer memory, (n)=320 15.500 37.900
FROMD Reading buffer memory, (n)=1 4.000 5.700
Reading buffer memory, (n)=1000 41.000 63.600
Reading host CPU buffer memory, (n)=1 1.400 2.900
Reading host CPU buffer memory, (n)=320 15.500 34.700
Reading another CPU buffer memory, (n)=1 4.000 5.700
Reading another CPU buffer memory, (n)=320 24.500 47.600
DFROMD Reading buffer memory, (n)=1 4.000 5.700
Reading buffer memory, (n)=500 41.400 70.400
Reading host CPU buffer memory, (n)=1 1.200 2.800
Reading host CPU buffer memory, (n)=320 22.400 45.300
Reading another CPU buffer memory, (n)=1 3.900 5.600
Reading another CPU buffer memory, (n)=320 34.000 62.800
TOD Writing to buffer memory, (n)=1 2.300 4.100
Writing to buffer memory, (n)=1000 47.100 76.000
Writing to host CPU buffer memory, (n)=1 1.200 2.700
Writing to host CPU buffer memory, (n)=320 13.700 37.600
DTOD Writing to buffer memory, (n)=1 2.300 4.100
Writing to buffer memory, (n)=500 46.300 81.400
Writing to host CPU buffer memory, (n)=1 1.000 2.800
Writing to host CPU buffer memory, (n)=320 17.200 46.500
TYPERD 10.500 25.400
Instruction name Condition Processing time (s)
Minimum Maximum