4. HOW TO MONITOR REDUNTANT SYSTEM
4 - 3
4
HOW TO MONITOR REDUNTANT SYSTEM
The following connection methods are available for the QCPU redundant system.
Connection to remote I/O station in MELSECNET/H network system
(1) Direct CPU connection (Remote I/O station of MELSECNET/H network system)
4.1.1 Direct CPU connection (Direct CPU connection to the remote I/O station)
(2) Computer link connection (Serial communication module mounted on remote I/O station of MELSECNET/H
network system)
4.1.2 Computer link connection (Connection to serial communication module mounted on remote
I/O station)
(3) Ethernet connection (Ethernet module mounted on the remote I/O station of the MELSECNET/H network
system)
4.1.3 Ethernet connection (Connection to Ethernet module mounted on remote I/O station)
Direct CPU connection
4.2 Direct CPU Connection
CC-Link connection (intelligent device station)
4.3 CC-Link Connection (Intelligent Device Station)
CC-Link connection (Via G4)
4.4 CC-Link Connection (Via G4)
MELSECNET/H connection, MELSECNET/10 connection (Network system)
4.5 MELSECNET/H and MELSECNET/10 Connections (Network Systems)
CC-Link IE Controller Network connection (Network system)
4.6 CC-Link IE Controller Network Connection (Network System)
Ethernet connection
4.7 Ethernet Connection
Connection to the redundant type extension base unit
(1) Computer link connection (Serial communication module mounted on the redundant type extension base unit)
4.8.1 Computer link connection (Connection to the Serial communication module mounted on the
redundant type extension base unit)
(2) Ethernet connection (Ethernet module mounted on the redundant type extension base unit)
4.8.2 Ethernet connection (Connection to the Ethernet module mounted on redundant type
extension base unit)
(3) CC-Link connection (intelligent device station) (CC-Link module mounted on the redundant type extension base
unit)
4.8.3 CC-Link connection (intelligent device station) (Connection to the CC-Link module
mounted on redundant type extension base unit)
(4) CC-Link connection (Via G4) (CC-Link module mounted on the redundant type extension base unit)
4.8.4 CC-Link connection (Via G4) (Connection to the CC-Link module mounted on redundant
type extension base unit)
For details of PLC CPUs that can be monitored in each connection method of GOT, refer to the following.
Monitorable controllers of each chapter

Table of Contents

Other manuals for Mitsubishi GOT2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT2000 Series and is the answer not in the manual?

Mitsubishi GOT2000 Series Specifications

General IconGeneral
Power Supply24VDC
SoftwareGT Works3
ProcessorRISC CPU
InterfaceEthernet, USB, RS-232, RS-422/485
Operating Temperature0°C to 50°C
Display TypeTFT LCD
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s² (15G), 11ms duration
Touch PanelAnalog Resistive