15 - 34
15. SERVO AMPLIFIER CONNECTION
15.6 Device Range that Can Be Set
(i) Alarm
(j) External input
(k) External output
(l) Input signal for test operation (for test operation)
(m) Forced output of signal pin (for test operation)
(n) Set data (for test operation)
Device name
Item Symbol
AL0 Current alarm number
AL1 Detailed data of current alarms
AL11
Servo status when alarm occurs cumulative
feedback pulses
AL12
Servo status when alarm occurs
servo monitor speed
AL13
Servo status when alarm occurs droop pulses
AL14
Servo status when alarm occurs cumulative
command pulses
AL15
Servo status when alarm occurs command
pulse frequency
AL16
Servo status when alarm occurs analog
speed command voltage
/limit voltage
AL17
Servo status when alarm occurs
analog torque command voltage
/limit voltage
AL18
Servo status when alarm occurs
regenerative load ratio
AL19
Servo status when alarm occurs effective
load ratio
AL20
Servo status when alarm occurs peak load
ratio
AL21
Servo status when alarm occurs
instantaneous torque
AL22
Servo status when alarm occurs within one-
revolution position
AL23 Load inertia moment ratio ABS counter
AL24
Servo status when alarm occurs
load inertia moment ratio
AL25 Servo status when alarm occurs bus voltage
AL200
Alarm number from alarm history
most recent alarm
AL201
Alarm number from alarm history
first alarm in past
AL202
Alarm number from alarm history
second alarm in past
AL203
Alarm number from alarm history
third alarm in past
AL204
Alarm number from alarm history
fourth alarm in past
AL205
Alarm number from alarm history
fifth alarm in past
AL210
Alarm occurrence time in alarm history
most recent alarm
AL211
Alarm occurrence time in alarm history
first alarm in past
AL212
Alarm occurrence time in alarm history
second alarm in past
AL213
Alarm occurrence time in alarm history
third alarm in past
AL214
Alarm occurrence time in alarm history
fourth alarm in past
AL215
Alarm occurrence time in alarm history
fifth alarm in past
AL230
Detailed alarm from alarm history
most recent alarm
AL231
Detailed alarm from alarm history
first alarm in past
AL232
Det
ailed alarm from alarm history
second alarm in past
AL233
Detailed alarm from alarm history
third alarm in past
AL234
Detailed alarm from alarm history
fourth alarm in past
AL235
Detailed alarm from alarm history
fifth alarm in past
Device
name
Item Symbol
DI0 Input device statuses
DI1 External input pin statuses
DI2
Statuses of input devices switched on
through communication
Device name Item Symbol
DO0 Output device statuses
DO1 External output pin statuses
Device name Item Symbol
TMI0 Input signal for test operation
Device name Item Symbol
TMO0 Forced output of signal pin
Device name Item Symbol
TMD0 Writes the speed (test mode)
TMD1
Writes the acceleration/
deceleration time constant
(test mode)
TMD2 For manufacturer setting
TMD3
Writes the moving distance
(test mode)