SleeperFeatures
Whentheenginestarts,thetemperatureandfanspeedwill
beadjustedautomaticallytorestoreandmaintainthedesired
temperature.
HeatModeandESPARHeater
TheAutoStart/Stopsystemmaybeusedinconjunctionwith
fuelredheaters.Thesystemisconguredtoworkwithor
withoutanESPARheater.
Forvehicle’sequippedwithanESPARheater,theAutoStart
/Stopsystemwillnotstartthetrucktoheatthevehicle.For
vehicleswithoutanESPARheater,theAutoStart/Stopsystem
willstartthevehicleforbothheatingandcooling.
Heatwillbeprovidedbythefuelredheater.Ifthevehicledoes
requireastartduetolowbatteryvoltageorcoldengineoil,the
fuelredheaterwillcontinuetooperate.
Theoperatormustengagetheheaterandchoosethedesired
temperaturesettingonthevehicle’scontrolpanel.
VehiclesEquippedwithESPARHeaters
Forvehicle’sequippedwithanESPARheater,theAutoStart/
Stopsystemwillnotstartthetrucktoheatthevehicle.
DONOTACTIVATEtherearHVACswitch.Theheat
modeofautomaticclimatecontrolwillbedisabledwith
thisconguration.
TheAutoStart/Stopsystemwillstarttheenginedueto
lowbatteriesandcoldoil.
TheESPARheaterwillcontinuetooperatewhiletheAuto
Start/Stopsystemrunstheengine.
ReleasingtheparkbrakedisablestheESPARHeater.
VehiclesNotEquippedwithESPARHeaters
ForvehiclesnotequippedwithanESPARheater,theAutoStart
/Stopsystemwillstartthevehicleforbothheatingandcooling.
Vehicleshouldbepre-conditionedtoacomfortablesleeper
temperature:
Selectdesiredtemperaturesettingonsleeperpanel
control(availablerangeis58
°
Fto84
°
F/14
°
Cto29
°
C).
EngageAutomaticClimateControl.
SetfrontHVACtothefullheatmodeandthefanspeed
totherstfanspeedsetting(sleeperfanspeedis
automaticallyadjustedto33%).
Thesystemmonitorssleepertemperaturefrom
thesensorlocatedinthecoldairreturn.When
sleepertemperatureislessthantheoperator-selected
temperatureby5
°
Formore,theengineisstarted(system
willincreasefanspeedfrom33%to50%).
ThesystemwillincreasethesleeperHVACpanel
temperaturesettingby10
°
F.Oncetargettemperatureis
achieved,asmeasuredbythesleepersensor,theengine
willcontinuetorununtiltheRUNTIMEtimerexpires.
WhentheRUNTIMEtimerexpires,theoperator-selected
temperaturewillberestoredtooriginalsetting.Fanspeed
isreturnedto33%andtheenginewillshutdown.
AprogrammableEngine-OFFtimerwillrequirethatthe
enginemustbeofffor15minutesbeforearestartis
permitted.
110