F RELIABILITY TESTING
We know our products play vital roles in the productions of our customers. Durability
and consistent, robust performance are much more than just adjectives for your
business and ours.
For this reason, all NewTek products undergo rigorous reliability testing to ensure
they meet our exacting test standards. For TriCaster 8000, 860 and 460, the following
standards are applicable:
Test Parameter
Evaluation Standard
Temperature
Mil-Std-810F Part 2, Sections 501 & 502
Ambient Operating
0°C and +40°C
Ambient Non-Operating
-10°C and +55°C
Humidity
Mil-STD 810, IEC 60068-2-38
Ambient Operating
20% to 90%
Ambient Non-Operating
20% to 95%
Vibration
ASTM D3580-95; Mil-STD 810
Sinusoidal
Exceeds ASTM D3580-95 Paragraph 10.4: 3 Hz to 500 Hz
Random
Mil-Std 810F Part 2.2.2, 60 minutes each axis,
Section 514.5 C-VII
Electrostatic Discharge
IEC 61000-4-2
Air Discharge
8K Volts
Contact
4K Volts