Remote Commands
R&S
®
FSW
1332User Manual 1173.9411.02 ─ 43
SYSTem:IFGain:MODE <Mode>
Configures the internal IF gain settings in HP emulation mode due to the application
needs. This setting is only taken into account for resolution bandwidth < 300 kHz and is
only available if a HP language is selected using SYSTem:LANGuage on page 1332.
Parameters:
<Mode> NORMal | PULSe
NORMal
Optimized for high dynamic range, overload limit is close to ref-
erence level.
PULSe
Optimized for pulsed signals, overload limit up to 10 dB above
reference level.
*RST: NORM
Example:
SYST:IFG:MODE PULS
Manual operation: See "IF Gain" on page 791
SYSTem:HPADditional <State>
Allows the use of HP commands in addition to SCPI commands for R&S
FSP/FSQ/FSU emulation (see SYSTem:LANGuage on page 1332).
Parameters:
<State> ON | OFF | 1 | 0
OFF | 0
Switches the function off
ON | 1
Switches the function on
*RST: 0
Manual operation: See "Language" on page 790
See "HP Additional" on page 792
SYSTem:LANGuage <Language>
This command selects the system language.
For details see Chapter 13.2, "GPIB Languages", on page 769.
Note:This command is also used to emulate previous R&S signal and spectrum ana-
lyzers, making the SYST:COMP command obsolete.
Note: For PSA89600 emulation, the option is indicated as "B7J" for the *OPT? query
("B7J, 140" if Wideband is activated).
Note: For R&S FSP/FSQ/FSU emulation, HP commands are not automatically also
allowed. In this case, set SYSTem:HPADditional to ON.