Remote Commands
R&S
®
FSW
948User Manual 1173.9411.02 ─ 43
Parameters:
<Bandwidth> Bandwidth in Hz
*RST: 10.0 MHz
Default unit: Hz
Example:
//Select the band category 1
ESP2:MSR:BCAT 1
//Set the base station class to medium range
ESP2:MSR:CLAS MED
//Set the maximum output power to 10 dBm.
ESP2:MSR:MPOW 10
//Set the frequency range of the base station to > 3 GHz
ESP2:MSR:BAND:HIGH
//Set the base station RF bandwidth to 20 MHz
ESP2:MSR:RFBW 20MHZ
//Calculate limits for MSR SEM
ESP2:MSR:APPL
Manual operation:
See "Base Station RF Bandwidth" on page 262
14.5.7.8 Configuring the List Evaluation
The following commands configure the list evaluation.
Useful commands for SEM measurements described elsewhere
●
MMEMory:STORe<n>:LIST on page 1253
Remote commands exclusive to SEM measurements
CALCulate<n>:ESPectrum:PSEarch:AUTO...................................................................... 948
CALCulate<n>:ESPectrum:PEAKsearch:AUTO.................................................................948
CALCulate<n>:ESPectrum:PSEarch[:IMMediate].............................................................. 949
CALCulate<n>:ESPectrum:PEAKsearch[:IMMediate].........................................................949
CALCulate<n>:ESPectrum:PSEarch:MARGin...................................................................949
CALCulate<n>:ESPectrum:PEAKsearch:MARGin............................................................. 949
CALCulate<n>:ESPectrum:PSEarch:PSHow.................................................................... 949
CALCulate<n>:ESPectrum:PEAKsearch:PSHow...............................................................949
CALCulate<n>:ESPectrum:PSEarch:AUTO <State>
CALCulate<n>:ESPectrum:PEAKsearch:AUTO <State>
This command turns the list evaluation on and off.
Suffix:
<n>
.
Window
Parameters:
<State> ON | OFF | 0 | 1
*RST: 1
Configuring and Performing Measurements