EasyManua.ls Logo

Rohde & Schwarz CMW 500 - Configuring a Spectrum Measurement

Rohde & Schwarz CMW 500
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S
®
CMW 500 GSM Applications
GSM Programming
Operating Manual 1202.3986.32 – 03 244
FPRINT ************************************************************
FPRINT Start continuous measurement, return an overview of all measurement results
FPRINT in the last measured cycle (with statistical evaluation).
FPRINT Query measurement state and substates (should be "RUN,ADJ,ACT").
FPRINT ************************************************************
CONFigure:GSM:MEASurement:MEValuation:REPetition CONTinuous
FETCh:GSM:MEASurement:MEValuation:MODulation:OVERview?
FETCh:GSM:MEASurement:MEValuation:STATe:ALL?
8.3.1.6 Configuring a Spectrum Measurement
FPRINT ************************************************************
FPRINT ACP Modulation configuration: Enable and define five frequency
FPRINT offsets, define evaluation areas
FPRINT ************************************************************
CONFigure:GSM:MEASurement:MEValuation:SMODulation:FOFFsets ON,
ON, ON, ON, ON, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF,
OFF, OFF, OFF, OFF, OFF, OFF
CONFigure:GSM:MEASurement:MEValuation:SMODulation:FOFFsets 0.1,
0.2, 0.25, 0.4, 0.6, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0,
0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0
CONFigure:GSM:MEASurement:MEValuation:SMODulation:EARea OFF, 0,
0, ON, 90, 147
FPRINT ************************************************************
FPRINT ACP Switching configuration: Enable and define five frequency FPRINT
offsets,
FPRINT set peak hold mode for ACP vs. frequency graphs only
FPRINT ************************************************************
CONFigure:GSM:MEASurement:MEValuation:SMODulation:FOFFsets ON,
ON, ON, ON, ON, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF,
OFF, OFF, OFF, OFF, OFF, OFF
CONFigure:GSM:MEASurement:MEValuation:SMODulation:FOFFsets 0.1,
0.2, 0.25, 0.4, 0.6, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0,
0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0
CONFigure:GSM:MEASurement:MEValuation:SMODulation:EARea OFF, 0,
0, ON, 90, 147
CMW: CONFigure:GSM:MEASurement:MEValuation:SSWitching:PHMode SCO
FPRINT ************************************************************
FPRINT Re-start measurement and return ACP results
FPRINT ************************************************************
深圳德标仪器 135-1095-0799