9.4.2.4 Statistical Settings (Modulation)
The following commands specify the scope of the modulation measurement.
CONFigure:WCDMa:MEAS<i>:MEValuation:MPERiod:MODulation <Meas.
Period>
Selects the width of the basic measurement period within each measured slot. Use
CONFigure:WCDMa:MEAS<i>:MEValuation:MSCount to define the number of
measured slots.
<Meas Period> FULLslot: Full slot measurement
HALFslot: Half slot measurement
Def. value: HALFslot
Example See Specifying Measurement-Specific Settings
Characteristics Firmware version V1.00
CONFigure:WCDMa:MEAS<i>:MEValuation:SCOunt:MODulation <Count>
Specifies the statistic count of the measurement; see Statistical Settings. The statistic
count is equal to the number of measurement intervals per single shot. Use
CONFigure:...:MEAS<i>:...:REPetition SINGleshot | CONTinuous to
select either single shot or continuous measurements.
<Count> Number of measurement intervals. A measurement interval
comprises a single power/frequency step.
Range: 1 to 1000
Def. value: 10
Example See Specifying Measurement-Specific Settings
Characteristics Firmware version V1.00
CONFigure:WCDMa:MEAS<i>:MEValuation:DMODe:MODulation <Detection
Mode>
Selects the detection mode for uplink WCDMA signals.
<Detection Mode> A3G: 3GPP Signal Auto
Def. value: A3G
Example See Specifying Measurement-Specific Settings
Characteristics Firmware version V1.00
CONFigure:WCDMa:MEAS<i>:MEValuation:AMODe:MODulation <Analysis
Mode>
Defines whether a possible origin offset is included in the measurement results