CMW 500 WiMAX Applications
WiMAX GUI Reference
Operating Manual 1202.3986.32 – 03 382
Multi Evaluation Configuration: Map of Bursts
Measurement Parameters > Map of Bursts > Rect. Subch. Offset
Specifies the start of the burst on the sub-channel axis. The logical sub-channels are
numbered starting from zero; an offset n means that sub-channel no. n is the first
logical sub-channel of the burst.
GPIB command:
CONFigure:WIMax:MEASurement<i>:MEValuation:RSUBoffset
Measurement Parameters > Map of Bursts > Rect. Offset Inside
Specifies the start of the burst (in symbol periods) on the time axis as an integer
number of symbol periods. The value must be an integer multiple of 3 (the number of
symbols per UL slot).
GPIB command: CONFigure:WIMax:MEASurement<i>:MEValuation:ROINside
Measurement Parameters > Map of Bursts > Rect. No of OFDMA Slots
Specifies the number of OFDMA slots (3-symbol periods comprising a single logical
sub-channel) within the measured burst.
GPIB command:
CONFigure:WIMax:MEASurement<i>:MEValuation:RNOofdmaslot
Measurement Parameters > Map of Bursts > Modulation
Specifies the modulation scheme of the analyzed burst. OFDMA symbols are
modulated according to one of the following modulation schemes: BPSK, QPSK,
16QAM, 64QAM.
GPIB command:
CONFigure:WIMax:MEASurement<i>:MEValuation:MODulation
10.2.1.7 Multi Evaluation Configuration: Trigger Settings
The "Trigger" settings configure the measurement trigger for the multi-evaluation
measurement.