R&S
®
CMW 500 WCDMA Applications
WCDMA Programming
Operating Manual 1202.3986.32 – 03 327
CONFigure:WCDMa:MEASurement:MEValuation:SCONdition SLFail
CONFigure:WCDMa:MEASurement:MEValuation:MOEXception ON
CONFigure:WCDMa:MEASurement:MEValuation:MSCount 30
CONFigure:WCDMa:MEASurement:MEValuation:PSLot 3
CCONFigure:WCDMa:MEASurement:MEValuation:MSLot SL0
FPRINT ************************************************************
FPRINT Specifiy modulation/CDP settings:
FPRINT Full slot measurement over 20 statistics cycles, analysis
FPRINT without origin offset, channel detection threshold -5 dB,
FPRINT statistical results in slot 4
FPRINT query detection mode (A3G, 3GPP Signal Auto)
FPRINT ************************************************************
CONFigure:WCDMa:MEASurement:MEValuation:MPERiod:MODulation FULL
CONFigure:WCDMa:MEASurement:MEValuation:SCOunt:MODulation 20
CONFigure:WCDMa:MEASurement:MEValuation:AMODe:MODulation NOOF
CONFigure:WCDMa:MEASurement:MEValuation:CDTHreshold:MODulation -
5
CONFigure:WCDMa:MEASurement:MEValuation:SSCalar:MODulation 4
CONFigure:WCDMa:MEASurement:MEValuation:DMODe:MODulation?
FPRINT ************************************************************
FPRINT Specify spectrum settings:
FPRINT select a measurement length of 30 slots (2 WCDMA frames)
FPRINT ************************************************************
CONFigure:WCDMa:MEASurement:MEValuation:SCOunt:SPECtrum 20
WAITKEY >General configuration completed, press "OK" to define
trigger<
9.3.1.5 Configuring the Trigger System
FPRINT ************************************************************
FPRINT Use fast synchronization to the RF input signal and a trigger timeout of 1 s.
FPRINT ************************************************************
CONFigure:WCDMa:MEASurement:TRIGger:SOURce FFRun
CONFigure:WCDMa:MEASurement:TRIGger:TOUT 1.0E+3
WAITKEY >Trigger settings completed, press "OK" to define
limits<
9.3.1.6 Specifying Limits
FPRINT ************************************************************
FPRINT Define all modulation limits