R&S
®
CMW 500 WCDMA Applications
WCDMA Programming
Operating Manual 1202.3986.32 – 03 328
FPRINT ************************************************************
CMW: CONFigure:WCDMa:MEASurement:MEValuation:LIMit:MERRor 20,
OFF
CMW: CONFigure:WCDMa:MEASurement:MEValuation:LIMit:EVMagnitude
20, 40
CMW: CONFigure:WCDMa:MEASurement:MEValuation:LIMit:PERRor 20,
OFF
CMW: CONFigure:WCDMa:MEASurement:MEValuation:LIMit:IQOFfset -20
CMW: CONFigure:WCDMa:MEASurement:MEValuation:LIMit:IQIMbalance
ON
CMW: CONFigure:WCDMa:MEASurement:MEValuation:LIMit:CFERror 150
FPRINT ************************************************************
FPRINT Define all ACLR limits
FPRINT ************************************************************
CMW: CONFigure:WCDMa:MEASurement:MEValuation:LIMit:ACLR:ABSolute
ON
CMW: CONFigure:WCDMa:MEASurement:MEValuation:LIMit:ACLR:RELative
-35, -47
FPRINT ************************************************************
FPRINT Define spectrum emission mask
FPRINT ************************************************************
CMW:
CONFigure:WCDMa:MEASurement:MEValuation:LIMit:EMASk:ABSolute -
50, -13, -15
CMW:
CONFigure:WCDMa:MEASurement:MEValuation:LIMit:EMASk:RELative -
50.5, -47.5, -37.5, -33.5, -48.275, -33.725
WAITKEY >Limit settings completed, press "OK" to start single-
shot measurement<
9.3.1.7 Performing Single Shot Measurements
FPRINT ************************************************************
FPRINT Start single-shot measurement, return magnitude error trace.
FPRINT Query the measurement state (should be "RDY").
FPRINT ************************************************************
READ:WCDMa:MEASurement:MEValuation:TRACe:EVMagnitude:RMS:AVERage
?
WAITKEY >Single-slot measurement completed, press "OK" to query
state and return all measurement results<