Rohde & Schwarz CMW 500 - Configure:gsm:meas<I>:Mevaluation:limit:gmsk:pvtime:upper:redge<Number>:Static; Configure:gsm:meas<I>:Mevaluation:limit:gmsk:pvtime:upper:upart<Number>:Static; Configure:gsm:meas<I>:Mevaluation:limit:pvtime:gplevel

Rohde & Schwarz CMW 500
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S
®
CMW 500 GSM Applications
GSM Command Reference
Operating Manual 1202.3986.32 – 03 275
CONFigure:GSM:MEAS<i>:MEValuation:LIMit:PVTime:GPLevel <Level>
Defines the raising of the upper limit line in the guard period between two consecutive
bursts.
<Level> Range: 0 dB to 10 dB
Def. value: 3 dB
Def. unit: dB
Characteristics Firmware version V1.00
CONFigure:GSM:MEAS<i>:MEValuation:LIMit:GMSK:PVTime:UPPer:REDGe<nu
mber>:STATic
CONFigure:GSM:MEAS<i>:MEValuation:LIMit:GMSK:PVTime:UPPer:UPARt<num
ber>:STATic
CONFigure:GSM:MEAS<i>:MEValuation:LIMit:GMSK:PVTime:UPPer:FEDGe<nu
mber>:STATic
CONFigure:GSM:MEAS<i>:MEValuation:LIMit:EPSK:PVTime:UPPer:REDGe<num
ber>:STATic
CONFigure:GSM:MEAS<i>:MEValuation:LIMit:EPSK:PVTime:UPPer:UPARt<num
ber>:STATic
CONFigure:GSM:MEAS<i>:MEValuation:LIMit:EPSK:PVTime:UPPer:FEDGe<num
ber>:STATic
<Time Start>, <Time End>, <Rel Start>, <Rel End>, <Abs Start Status> | <Abs
Start>, <Abs End Status> | <Abs End>, <Status Area>
These commands define and activate upper limit lines for the measured power vs.
time. The lines apply to the modulation schemes GMSK or 8PSK (EPSK). Each line
consists of three sections: rising edge (REDGe), useful part (UPARt) and falling edge
(FEDGe). Each section consists of several areas for which relative and absolute limits
can be defined (if both are defined the higher limit overrules the lower one).
<number> Number of the area
Range rising/falling edge: 1 to 4
Range useful part: 1 to 3
Def. value: 1
<Time Start>,
<Time End>,
Start and end time of the area
Range: -50 fs to +600 fs
Def. values: see table below
<Rel Start>,
<Rel End>,
Start and end level of the relative limit for the area
Range: -100 dB to +20 dB
Def. values: see table below