R&S
®
CMW 500 GSM Applications
GSM Command Reference
Operating Manual 1202.3986.32 – 03 248
(CONFigure:...:MEAS<i>:RFSettings:ENPower) minus the external input
attenuation (CONFigure:...:MEAS<i>:RFSettings:EATTenuation) in order to
determine its reference power. The reference power must be within the power range of
the selected input connector; refer to the "Specifications".
<User Margin> Range: 0.00 dB to +50.00 dB at RF 1 COM (increment 0.01 dB)
Def. value: 0.00 dB
D
e
f. unit: dB
Example See Specifying General Measurement Settings
Characteristics Firmware version V1.00
CONFigure:GSM:MEAS<i>:RFSettings:FREQuency <Frequency>
Selects the center frequency of the RF analyzer.
<Frequency> Range: 100 MHz to 3300 MHz (increment 0.1 Hz)
Def. value 903.000 MHz
Def. unit: Hz
Example See Specifying General Measurement Settings
Characteristics Firmware version V1.00
8.4.2 GSM Multi Evaluation Measurement Commands
The commands valid for the GSM "Multi Evaluation" measurement are divided into the
groups listed below. For an overview of the commands refer to Command Groups.
Commands for control and configuration:
Measurement Control and States
Enabling Results and Views
Statistical Settings
Measurement Settings
Trigger Settings
Power vs. Time Settings
Spectrum Modulation Settings
Spectrum Switching Settings
Limits (GMSK Modulation)
Limits (8PSK Modulation)
Limits (Power vs. Time)
Limits (Spectrum Modulation)
Limits (Spectrum Switching)
Filter Settings
Commands for retrieval of measurement results:
EVM Measurement Results (Trace)
EVM Measurement Results (Single Values)