R&S
®
CMW 500 GSM Applications
GSM Command Reference
Operating Manual 1202.3986.32 – 03 257
<Status> ON: Evaluate results and show view
OFF: Do not evaluate results, hide view
Def. value: ON (all except SMTime and SSTime)
Example See Configuring a Spectrum Measurement
Characteristics Firmware version V1.00
CONFigure:GSM:MEAS<i>:MEValuation:RESult:AMPM <Status>
Enables or disables the evaluation of the AM-PM results.
<Status> ON: Evaluate results
OFF: Do not evaluate results
Def. value: OFF
Example See Configuring a Spectrum Measurement
Characteristics Firmware version V1.00
8.4.2.4 Statistical Settings
The following commands specify the scope of the measurement.
CONFigure:GSM:MEAS<i>:MEValuation:REPetition <Mode>
Specifies the repetition mode of the measurement; see Statistical Settings. The
repetition mode specifies whether the measurement is stopped after a single shot or
repeated continuously. Use CONFigure:..:MEAS<i>:...:SCOunt to determine the
number of measurement intervals per single shot.
<Mode> SINGleshot: Single shot measurement
CONTinuous: Continuous measurement
Def. value: SINGleshot
Example See Single Shot and Continuous Measurements
Characteristics Firmware version V1.00
CONFigure:GSM:MEAS<i>:MEValuation:SCOunt:PVTime <Count>
Specifies the statistic count of the measurement; see Statistical Settings. The statistic
count is equal to the number of measurement intervals per single shot. Use
CONFigure:...:MEAS<i>:...:REPetition SINGleshot | CONTinuous to
select either single shot or continuous measurements.