CLI Reference SEM Configuration Commands
le: less than or equal to
lt: less than
ne: unequal to
entry-val
entry-value
The value that triggers comparison.
entry-type {value |
increment | rate}
The value type that triggers comparison.
exit-comb {or |
and}
The relation between exit-op and exit-time.
exit-op operator
The method to recover comparison (optional):
eq: equal to
ge: greater than or equal to
gt: greater than
le: less than or equal to
lt: less than
ne: unequal to
exit-val exit-value
The value to recover comparison (optional)
exit-type {value |
increment | rate}
The value type to recover comparison
(optional).
exit-time
exit-time-value
The minimum time between triggering the
policy and monitoring recovery (optional).
average-factor
average-factor-value
It is used by rate, and is the changed
statistical period when multiplied by
poll-int-value
poll-interval
poll-int-value
The comparing interval. By default, it is 5s.
Default
configuration
No event is configured.
Command
mode
SEM configuration mode
Usage
Guideline
Available events:
Variable Name
Function
_snmp_oid
SNMP OID
_snmp_oid_delta_val
Difference between the actual
SNMP OID value and the set
value