CLI Reference NFPP Configuration Commands
arp-guard monitor-period
Use this command to configure the arp guard monitor time.
arp guard monitor-period seconds
Parameter
description
Parameter
Description
seconds
Set the monitor time, in seconds. The
valid range is [180, 86400].
Default
Settings
600s
Command
mode
NFPP configuration mode.
Usage
guidelines
When the attacker is detected, if the isolate period is
0, the attacker will be monitored by the software and
the timeout time will be the monitor period. During the
software monitoring, if the isolate period is not 0, the
software-monitored attacker will be auto-isolated by
the hardware and the timeout time will be the isolate
period. The monitor period is valid with the isolate
period 0.
If the isolate period has changed to be 0, the
attackers on the interface will be removed rather than
being monitored by the software.
Examples
Ruijie(config)# nfpp
Ruijie(config-nfpp)# arp-guard monitor-period 180
Related
commands
Command
Description
show nfpp arp-guard
summary
Show the configurations.
show nfpp arp-guard
hosts
Show the monitored host list.
clear nfpp arp-guard
hosts
Clear the isolated host.
arp-guard monitored-host-limit
Use this command to set the maxmum monitored host number.