CLI Reference CFM Configuration Commands
Related
commands
Command
Description
show cfm mep
service-instance
Show the MEP (maintenance
association end point) configurations.
cfm linktrace service-instance mep ttl
Use this command to execute the linktrace function.
cfm linktrace service-instance instance-id mep mep-id {remote-mep remote-mep-id | remote-mac mac-address}
[ttl ttl-value] [hw-only]
Parameter
description
Parameter
Description
instance-id
Service instance id, in the range of
1-32767.
mep-id
MEP (maintenance association end
point) id, in the range of 1-8191.
remote-mep
remote-mep-id
Remote MEP id.
remote-mac
mac-address
MAC address of the remote MP
(including the maintenance association
end point and maintenance domain
intermediate point).
ttl ttl-value
The maximum tops for the LTM
forwarding, in the range of 1 to 255.
hw-only
This option means performing the LTM
forwarding according to the FDB table
only.
Default
By default, the ttl-value is 64 and the hw-only is disabled.
Command
mode
Privileged EXEC mode.
Usage
guidelines
N/A.
Examples
Ruijie# cfm linktrace service-instance 1 mep 100 remote-mep 200 ttl
80 hw-only
Ruijie#cfm linktrace service-instance 1 mep 100 remote-mac
00d0.f800.1e2f ttl 30

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruijie RG-S2600G-I Series and is the answer not in the manual?

Ruijie RG-S2600G-I Series Specifications

General IconGeneral
BrandRuijie
ModelRG-S2600G-I Series
CategorySwitch
LanguageEnglish

Related product manuals