Parameters related to NFC counter (omissible)
1: enabled (automatically updates counter when
READ command is executed)
0: disabled
cfl: NFC counter password restriction CFG1:ACCESS:NFC_CNT_PWD_PROT
Sets availability of NFC counter password restriction.
Valid range: 0 or 1
0: disabled (password not valid)
1: enabled (password is valid)
Parameters related to configuration for authentication (omissible)
lma: Set address for password-lock Sets the address to the block that requires password
check.
Valid range: 0-255, 3-digit decimal
A parameter error will occur if a value exceeding
specified inlet capacity is specified.
IC Chip type Product Valid address
00 NTAG203 -
01 NTAG210 0 to 11
03 NTAG213 0 to 35
04 NTAG215 0 to 123
05 NTAG216 0 to 221
30 MIFARE
Ultralight
-
31 MIFARE
Ultralight (EV1)
(MF0UL11)
0 to 11
33 MIFARE
Ultralight C
-
62 my-d move
NFC
(*)
-: No password
*: my-d move NFC is excluded because it is applied
to a fixed area.
prt: Set protection format Sets the type of restriction.
Valid range: 0 or 1
0: write protect
1: read-write protect
Note: When designated for my-d move NFC, regardless of
set value this setting:
(1) Cannot be canceled.
(2) "dlk" cannot be used.
acl: Lock authentication configuration
information
Locks authentication configuration except for
password.
Valid range: 0 or 1
Unlockable after locking.