473
Parameters related to configuration for authentication (omissible)
Perma-lock is implemented when 1 is specified.
Nothing is implemented when 0.
lim: Set number of retries for
authentication
Sets number of retries when password authentication
fails.
Valid range: 0 to 7
* Note: When set to 7 or multiple instances add up to 7 or
more with my-d move NFC, setting cannot be changed.
Parameters related to access password (omissible)
apw: Access password Specify an 8-digit fixed hexadecimal when you want
to lock/read-protect with password.
pck: Set data to return when password
confirmation is successful
Specify a 4-digit fixed hexadecimal data to return
when the password check is successful.
psw: Specify unlock password Specify the same numerals used to lock the area
which is password locked/read-locked.
sa0: Access restriction area Specify a 2-digit fixed decimal within 00-35 for the
block to protect, dedicated for MIFARE Ultralight C.
sa1: Access restriction method Specify the contents of restriction dedicated for
MIFARE Ultralight C.
00: read-write protect
01: write protect
sak: Specify access password Specify a 32-character fixed hexadecimal when
locking/read-protecting with password, dedicated for
MIFARE Ultralight C.
aky: Specify unlock password Specify the same numerals used to lock the area
which is password locked/read-locked, dedicated for
MIFARE Ultralight C.
Parameters related to feed control (omissible)
fsw: Specify feed without printing Normally, RFID write print jobs that don’t include print
data writes but don't feed label. (Except for cases
with tag offset as default)
When 1 is specified for this parameter, even the print
jobs that don’t include print data will feed.
When 0 is specified, print jobs that don’t include print
data will not feed, which is the same as not specifying
fsw:. Also, printer only writes without feeding or
printing when 0 is specified for print jobs that include
print data, which allows write test without having to
waste label.
If labels are not fed, short buzzer will sound 2 times
when write is successful.
Short buzzer will the sound 6 times when writing fails.
In addition, if 2 is specified for the item including
print data, a write test can be performed without
consuming a label as only write is executed without
feed/print.
Valid range: 0 to 2