EasyManua.ls Logo

SATO CL6NX - [Information] Menu

SATO CL6NX
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
488
[Format of UID return data]
“Specify memory” + “:” + “Data” + “Line feed(0DH, 0AH)”
ee:f…f[CR][LF]
[UID return data]
Symbol Parameter name Valid range
e Specify memory UD: UID
f Data Maximum 14 digits
[Return data format (when a command error occurs)]
[NAK]<15>
16
[Exception processing]
Exception conditionParameter name
A value outside the range is specified The specified size and
received size are different
Identifier Command error Invalid receive data
Terminology Description
Command error The data received after a command error is determined is not
considered as a parameter of this command.
Invalid receive data The data corresponding to Byte 2 and thereafter of the identifier is
ignored.
[Coding Sample]
<A>
<RU>,01
<RK>1,D13,4912345678904
<XM>4912345678904
<Z>
[Sample of status reply]
When [DC2]PK is received using a tag with 04123456789ABC of UID.
Write successful (UID read successful)
[STX]23,1,N,UD:04123456789ABC[CR][LF][ETX]
Write successful(UID read fail)
[STX]9,1,D,UD:[CR][LF][ETX]
Write fail (UID read failed)
[STX]9,0,D,UD:[CR][LF][ETX]
[Supplemental explanation]
The write status and UID is returned when [DC2]PK is received after RFID write.
Although write is successful status will be returned without data if you fail to read UID since UID
read will be done separately from write.