63
[Supplementary Explanation]
• When the parameter "aaaa" and "bbbbb" are not specified, all print data specified prior to this
command will be rotated.
• Data outside of printing area will not rotate.
• If specifying this command for the item that does not contain print data, the command error will
occur.
• This command cannot be used in combination with the commands that associated with reedition
of print data. Refer to the invalid commands list below. When the command that cannot use in
combination with is specified, print result is not guaranteed.
• This command cannot be used in combination with some registration commands. Refer to
the invalid commands list below. When the command that cannot use in combination with is
specified, print result is not guaranteed.
• This command cannot be used in combination with some of the modification commands. Refer
to the invalid commands list below. When the command that cannot use in combination with is
specified, print result is not guaranteed.
• This command prints the mirror image of the print data put before the mirror rotation command
is specified. The data after the command does not rotate. Note that specifying this command
several times results rotating the data several times.
• When the mirror image is applied for the barcode, reading of the barcode and the head damage
check are not guaranteed.
• When executing the mirror image, the head damage check will be performed for all the areas
where rotated.
[Valid Range for start position of mirroring]
Valid range (dots)Model Head density
Horizontal start
position of mirror
rotation specification
Vertical start position
of mirror rotation
specification
203 dpi 1 to 832 1 to 20000
305 dpi 1 to 1248 1 to 18000
CL4NX
609 dpi 1 to 2498 1 to 9600
203 dpi
1 to 1216
*1
1 to 1340
*2
1 to 20000CL6NX
305 dpi
1 to 1984
*1
1 to 2010
*2
1 to 18000
*1 Valid range when "Head Base Position" is set to "Standard".
*2 Valid range when "Head Base Position" is set to "Left-justify".
[Valid Range for mirror rotation]
Valid range (dots)Model Head density
Horizontal range
of mirror rotation
Vertical range of
mirror rotation
203 dpi 8 to 832 8 to 20000CL4NX
305 dpi 8 to 1248 8 to 18000