64
Valid range (dots)Model Head density
Horizontal range
of mirror rotation
Vertical range of
mirror rotation
609 dpi 8 to 2498 8 to 9600
203 dpi
8 to 1216
*1
1 to 1340
*2
8 to 20000CL6NX
305 dpi
8 to 1984
*1
8 to 2010
*2
8 to 18000
*1 Valid range when "Head Base Position" is set to "Standard".
*2 Valid range when "Head Base Position" is set to "Left-justify".
[Invalid Commands]
Command
that
associated
with
reediting.
<WD> <F> <(> <0> <WA>
Registration <GI> <GT> <PI>
Modification <%>
Parent topic Modification Command