678
Setting name Setting range Default value
(Factory setting)
Cycle of ARP notification "0" to "600"(seconds) 0
KEEPALIVETIME "30" to "300"(seconds) 180
KEEPALIVECOUNT "1" to "99"(times) 17
SOCKET_CANCEL "0" : Normal mode
"1" : Compatible mode
0
Communication protocol
(SBPL)
Status 4 (Cycle)
Status 4 (ENQ)
Status 3
Status 5
none
Status 4 (ENQ)
Status 5
 
BCC check Enabled
Disabled
Disabled
TCP Connection Queue Enabled
Disabled
Enabled
Port number 1
1 to 65535
*1
1024
Port number 2
1 to 65535
*1
1025
Port number 3
1 to 65535
*1
9100
SNTP functionality Enabled
Disabled
Disabled
SNTP server IPv4 address 0.0.0.0 to 255.255.255.255 0.0.0.0
SNTP error notification
functionality
Enabled
Disabled
Disabled
SNMP setting Enabled
Disabled
Disabled
SNMP sysContact 0 to 255 of character string
SNMP sysName 0 to 255 of character string
SNMP sysLocation 0 to 255 of character string
SNMP read-only version 1|2c|3
1|2c
3
Disabled
1|2c|3
SNMP read-only community
name
The maximum of 32 character string public
SNMP read-only user name 8 to 32 of character string rouser
SNMP read-only security none
Authentication
Privacy (with encryption)
none
SNMP read-only authentication
protocol
MD5
SHA
MD5

Table of Contents