Section02MAINTENANCE
Subsection 04 (STORAGE)
F08E0MA
1
XP DI MODELS
1. Bleed outlet hose
Continue to pour until antifreeze appears at the en-
gine drain hose (crankcase cooling outlet). Then,
install a hose pincher on this hose.
F08E0JA
1
1. Engine drain hose (crankcase cooling outlet)
Continue to pour until antifreeze flows in air com-
pressor water outlet hose.
F08E0EA
1
XP DI MODELS
1. Air compressor water outlet hose
The pouring operation is over.
Remove pinchers in this order to allow proper flow
of antifreeze.
smr2004-Complete Line Up 47