Communication
11.2 PROFINET
S7-1200 Programmable controller
904 System Manual, V4.2, 09/2016, A5E02486680-AK
STATUS*
ERR_LOC*
Explanation
C080_9500 0001_000x Error in the system data type IF_CONF_V4, IF_CONF_NOS, or IF_CONF_NTP:
The values of two parameters are inconsistent.
C080_C200 0000_0000 Error at call of the instruction:
The configuration data cannot be transferred. Possible cause: The PROFINET interface is
not accessible.
C080_C300 0000_0000 Error at call of the instruction:
Insufficient resources (for example, multiple calling of "T_CONFIG" with different parame-
ters).
C080_C400 0000_0000 Error at call of the instruction:
Temporary communication error. Time indication for change to daylight saving time.
C080_D200 0000_0000 Error at call of the instruction:
Call not possible. Instruction is not supported by the selected PROFINET interface.
CONF_DATA Data block
The following diagram shows how the configuration data to be transferred is stored in the
configuration DB.
Configuration DB
Subfield 2
Configuration data
Subfield
n
Subfield 1
Subfield-specific parameters
The configuration data of CONF_DB consists of a field that contains a header
(IF_CONF_Header) and several subfields. IF_CONF_Header provides the following
elements:
field_type_id (data type UInt): Zero
field_id (data type UInt): Zero
subfield_cnt (data type UInt): Number of subfields