Chapter 6—Configuring and Managing Partitions Creating a Storage Partition
August 2017 User Guide—Spectra T50e Library
178
2. EnableandconfigurethePreScanandPostScanoptionsforthepartition.
Notes: Theav ailablePostScanoptionsdependonwhetherthe
partitionusesLTO‐4andlatergenerationdrivesandwhether
ornotaGlobalSparedriveisassignedtothepartition.
TheautomaticPostScanoperationconfiguredonthisscreen
onlyverifiesMLM‐enabledLTOcartridges.Ifyourpartition
usesLTOcartridgesthatarenotMLM‐enabled,youmust
addthemtothePostScanqueuemanually(seeSchedulea
ManualPostScanonpage251).
Figure 114 Enable PreScan and select the PostScan option and triggers.
To enable PostScan for the partition you must select one of the PostScan options
(FullScan, Quick Scan, or QuickScan using Global Spares) and one or more of the
Scan triggers.
Select the PostScan option you want to use.
The QuickScan options are only available for
LTO-4 and later generation Fibre Channel and
SAS drives.
If the partition does not include a Global Spare
drive, QuickScan is the only available option.
Select one or more triggers to enable the
selected PostScan option.
Select this option... To.. . Default
Enable PreScan EnablethePreScanfeature.Whenenabled,PreScanreplacesthe
morebasicMediaAutoDiscoveryprocess.See
UsingPreScanon
page245forinformationaboutthisoption.
Cleared
(Disabled)