Chapter 15—Maintaining the Drives Updating Drive Firmware
August 2017 User GuideSpectra T50e Library
449
Discontinue Background Operations
Youcannotupdatedrivefirmwareifthelibraryisactivelyrunningany
backgroundoperations,including
MediaAutoDiscovery,
PreScan,and
PostScan.
IfyoudonotwanttowaitforaMediaAutoDiscovery,PreScan,or
PostScanoperationtocomplete,youcanstoptheMediaAutoDiscoveryor
PreScanoperationorpausethePostScanoperation.Forotherbackground
operations,waitfortheprocesstocomplete.
ClickStop Discovery ontheMediaLifecycleManagementToolsscreen
tostopaMediaAutoDiscoveryorPreScanoperation.
ClickPause PostScanontheMediaLifecycleManagementToolsscreen
topausethePostScanoperationforonehour.
Discontinue Backups and Empty the Drives
Beforebeginningthedrivefirmwareupdateprocess,discontinueall
backupoperationsandremoveanycartridgesfromthedrives.
Ifpossible,useyourstoragemanagementsoftwaretomoveany
cartridgesthatarecurrentlyindrivesbacktotheirstoragelocations.
Ifyoucannotuseyourstoragemanagementsoftware,thenmove
thecartridgesasdescribedinMoveCartridgesWithinaPartitionon
page219.
Import the Firmware Update Tape
1. Logintothelibraryasauserwithsuperuseroradministrator
privileges.
2. ClickMENU,thenselectGeneral > Import/Export.TheImport/Export
screendisplaysshowinginformationforthelastpartitionthatwas
viewedoneithertheImport/ExportscreenortheInventoryscreen.
Caution
Attempting to update the firmware while the library is busy or when the drives
contain tapes may result in the update failing, failed backup jobs, or permanent
damage to the drives. If you have not already done so, stop all backup operations
and remove all tapes from the drives you are upgrading.