59 Programmable Hardware Manual (PHM)
© Tibbo Technology Inc.
To further lower the operating temperature of the EM1206 we advise you to arrange
a copper area on the host PCB and in contact with the heat-conductive sticker.
Best results are achieved when the copper area is larger, and also when two copper
areas are provided on both sides of the host PCB and interconnected by a number
of large vias.
Mechanical Dimensions
L
Max.
33.4
Length
W
Max.
18.1
Width
H
Max.
4.2
Height
l1
Aver
.
14.4
Length of the narrower part of the board
w
Max.
16.7
Width at the narrower part of the board