Phaser 6180 Color Laser Printer Service Manual 3-101
Error Messages and Codes
Environmental (Humidity/Temperature) Sensor Error
The Environmental Sensor has detected temperature error.
Applicable Chain Link
■ Chain Link 092-661: Environmental Sensor Error
Initial Actions
■ Cycle printer power.
■ If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts Wiring and Plug/Jack Map References
■ MCU Board, PL9.1.20
■ Humidity Sensor, PL9.1.19
■ Humidity Harness, PL10.1.4
■ “Map 4 - LVPS and MCU Board” on 
page 10-13
■ “Xerographic” on page 10-40
Troubleshooting Procedure Table 
Step Actions and Questions Yes No
1 Check the Humidity/Temperature 
Sensor for correct installation. Is the 
Humidity/Temperature Sensor 
correctly installed?
Go to step 2. Reseat the 
Humidity/
Temperature 
Sensor. Go to 
step 2.
2 Does the error still occur? Go to step 3. Complete.
3 Check the wiring harness connectors 
P/J26 and P/J261 between the MCU 
Board and the Humidity/Temperature 
Sensor. Are the connectors securely 
connected?
Go to step 4. Reconnect the 
connectors.
4 Check the Humidity/Temperature 
Harness for continuity.
1. Disconnect P/J26 and P/J261.
2. Check continuity between P/J26 <=> 
P/J261.
Go to step 5. Replace the 
Humidity/
Temperature 
Harness.
5 Check the Humidity/Temperature 
Sensor signal.
1. Disconnect P/J26 from the MCU 
Board.
2. Is there +5 V across ground <=> 
J26-4?
Replace the 
Humidity Sensor 
(page 8-86).
Replace the 
MCU Board 
(page 8-87).