4-32 Phaser 6180 Color Laser Printer Service Manual
General Troubleshooting
CRU Sensor M (Magenta Toner Cartridge Sensor)
Caution
When performing this procedure, remove and cover the Print Cartridges
to avoid exposure to light.
1. Enter the Service Diagnostic menu (page 4-5).
2. Open the Front Cover.
3. Remove the Transfer Unit (page 8-7).
4. Remove the Print Cartridges (page 8-9).
5. Perform the CRU Sensor M test: Engine Diag > Sensor Test > CRU
Sensor M.
6. Install and remove the Magenta Print Cartridge while checking the
information on the Control Panel display. The Low and High values
change from 0 up to 99.
7. Press the Cancel button to stop the CRU Sensor M test.
Control Panel
Normal
CRU Sensor M
L-0
CRU Sensor M
H-0
s6180-353