Phaser 6180 Color Laser Printer Service Manual 10-41
Plug/Jack and Wiring Diagrams
Signal Line Name Description
CLOCK Controls signal of the EEPROM Board.
DATA
ADC SOL ON (L) +24 VDC On/Off signal of the ADC Solenoid.
ADC SENSOR Toner patch density data measured by the ADC Sensor
(Analog value).
LED REM Removes signal of the LED of the ADC Sensor.
ADC V MONI Controls signal of the ADC Sensor.
DATA Controls signal of the EEPROM Board.
CLOC
TEMP. Temperature data in the printer by the Humidity/
Temperature Sensor (Analog value).
HUMI. Provides Humidity/Temperature data in the printer by
the Humidity/Temperature Sensor (Analog value).
ERASE K ON (L) +3.3 VDC On/Off signal of the LED.
ERASE Y/M/C ON (L) +3.3
VDC