Table 5.7 High Starting Torque, Settings 8 to B
Setting = 8
50 Hz Setting = 9 50 Hz Setting = A 60 Hz Setting = B 60 Hz
0
12
200
1.3 2.5 50
19
Voltage (V)
Frequency (Hz)
Voltage (V)
Frequency (Hz)
0
13
200
1.3 2.5 50
24
Voltage (V)
Frequency (Hz)
0
12
200
1.5 3 60
19
Voltage (V)
Frequency (Hz)
0
15
200
1.5 3 60
24
Table 5.8 Rated Output Operation, Settings C to F
Setting = C
90 Hz Setting = D 120 Hz Setting = E 180 Hz Setting = F 60 Hz
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 9060
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 12060
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 18060
0
12
16
200
1.5 3 60
Voltage (V)
Frequency (Hz)
V/f Patterns for 5.5 to 18.5 kW Drives
The following graphs are for 200 V class drives. Double values when using a 400 V class drive.
Table 5.9 Rated Torque Characteristics, Settings 0 to 3
Setting = 0
50 Hz Setting = 1 60 Hz Setting = 2 60 Hz Setting = 3 72 Hz
0
7
200
1.3 2.5 50
14
Voltage (V)
Frequency (Hz)
0
7
14
200
1.5 3 60
Voltage (V)
Frequency (Hz)
0
7
14
200
1.5 3 6050
Voltage (V)
Frequency (Hz)
0
7
14
200
1.5 3 7260
Voltage (V)
Frequency (Hz)
Table 5.10 Derated Torque Characteristics, Settings 4 to 7
Setting = 4
50 Hz Setting = 5 50 Hz Setting = 6 60 Hz Setting = 7 60 Hz
0
6
200
1.3 25 50
35
Voltage (V)
Frequency (Hz)
0
7
200
1.3 25 50
50
Voltage (V)
Frequency (Hz)
0
6
200
1.5 30 60
35
Voltage (V)
Frequency (Hz)
0
7
200
1.5 30 60
50
Voltage (V)
Frequency (Hz)
Table 5.11 High Starting Torque, Settings 8 to B
Setting = 8
50 Hz Setting = 9 50 Hz Setting = A 60 Hz Setting = B 60 Hz
0
9
200
1.3 2.5 50
18
Voltage (V)
Frequency (Hz)
0
11
200
1.3 2.5 50
23
Voltage (V)
Frequency (Hz)
0
9
200
1.5 3 60
18
Voltage (V)
Frequency (Hz)
0
13
200
1.5 3 60
23
Voltage (V)
Frequency (Hz)
Table 5.12 Constant Output, Settings C to F
Setting = C
90 Hz Setting = D 120 Hz Setting = E 180 Hz Setting = F 60 Hz
0
7
14
200
1.5 3 9060
Voltage (V)
Frequency (Hz)
0
7
14
200
1.5 3 12060
Voltage (V)
Frequency (Hz)
0
7
14
200
1.5 3 18060
Voltage (V)
Frequency (Hz)
0
7
14
200
1.5 3 60
Voltage (V)
Frequency (Hz)
Note: Increasing the voltage in the V/f pattern increases the available motor torque. However, when setting a custom V/f pattern,increase the voltage gradually while monitoring the
motor current, to prevent drive faults as a result of motor over-excitation and motor overheating or excessive vibration
5.5 E: Motor Parameters
148
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)